  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeAC/DC
Rated voltage400V
Frequency50 - 60Hz
Rated current32A
Release characteristicD
Pollution degree3
Current limiting class3
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Number of protected poles3
Flush-mounted installationNo
Over voltage category3
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Additional equipment possibleYes
Number of poles (total)3
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired0 - 70mm²
Explosion-proofNo
Power loss11.1W
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863002R0321 | S803S-D32-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC/DC

Rated voltage

400V

Frequency

50 .. 60Hz

Rated current

32A

Release characteristic

D

Pollution degree

3

Current limiting class

3

Concurrently switching neutral conductor

Width in number of modular spacings

3

Number of protected poles

3

Flush-mounted installation

Over voltage category

3

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Additional equipment possible

Number of poles (total)

3

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Explosion-proof

Power loss

11.1W

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V