Technical specifications

Rated current40A
Frequency50 - 60Hz
Built-in depth82.5mm
Concurrently switching neutral conductorNo
Release characteristicB
Pollution degree3
Over voltage category3
Rated insulation voltage Ui690V
Rated voltage400V
Voltage typeAC
Explosion-proofNo
Degree of protection (IP)IP20
Current limiting class3
Number of protected poles3
Power loss11.1W
Width in number of modular spacings3
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)3
Connectable conductor cross section multi-wired0 - 70mm²
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863002R0405 | S803S-B40-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

40A

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Concurrently switching neutral conductor

Release characteristic

B

Pollution degree

3

Over voltage category

3

Rated insulation voltage Ui

690V

Rated voltage

400V

Voltage type

AC

Explosion-proof

Degree of protection (IP)

IP20

Current limiting class

3

Number of protected poles

3

Power loss

11.1W

Width in number of modular spacings

3

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

3

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.