Aleta.hr
Main Product Image

2CCS863002R0467 | S803S-K16-R HIGH PERFORMANCE MCB

Code: 1858544

ManufacturerABB
Catalog number2CCS863002R0467
EAN code7612271209537

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated voltage400V
Release characteristicK
Rated current16A
Built-in depth82.5mm
Frequency50 - 60Hz
Over voltage category3
Rated insulation voltage Ui690V
Current limiting class3
Pollution degree3
Explosion-proofNo
Width in number of modular spacings3
Power loss9.3W
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Number of protected poles3
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Rated impulse withstand voltage Uimp8kV
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Suitable for flush-mounted installationNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863002R0467 | S803S-K16-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated voltage

400V

Release characteristic

K

Rated current

16A

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Over voltage category

3

Rated insulation voltage Ui

690V

Current limiting class

3

Pollution degree

3

Explosion-proof

Width in number of modular spacings

3

Power loss

9.3W

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Number of protected poles

3

Concurrently switching neutral conductor

Flush-mounted installation

Rated impulse withstand voltage Uimp

8kV

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.