Aleta.hr
Main Product Image

2CCS863002R0504 | S803S-C50-R HIGH PERFORMANCE MCB

Code: 1858548

ManufacturerABB
Catalog number2CCS863002R0504
EAN code7612271207199

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicC
Power loss12.9W
Rated current50A
Voltage typeAC
Rated insulation voltage Ui690V
Degree of protection (IP)IP20
Width in number of modular spacings3
Concurrently switching neutral conductorNo
Over voltage category3
Ambient temperature during operating-25 - 60°C
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Explosion-proofNo
Connectable conductor cross section solid-core0 - 50mm²
Pollution degree3
Number of protected poles3
Rated voltage400V
Current limiting class3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)3
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863002R0504 | S803S-C50-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

C

Power loss

12.9W

Rated current

50A

Voltage type

AC

Rated insulation voltage Ui

690V

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Concurrently switching neutral conductor

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Explosion-proof

Connectable conductor cross section solid-core

0 .. 50mm²

Pollution degree

3

Number of protected poles

3

Rated voltage

400V

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

3

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.