Aleta.hr
Main Product Image

2CCS864002R0081 | S804S-D8-R HIGH PERFORMANCE MCB

Code: 1858608

ManufacturerABB
Catalog number2CCS864002R0081
EAN code7612271411596

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeAC
Number of poles (total)4
Release characteristicD
Over voltage category3
Frequency50 - 60Hz
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Rated current8A
Concurrently switching neutral conductorNo
Number of protected poles4
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 70mm²
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Current limiting class3
Width in number of modular spacings4
Pollution degree3
Explosion-proofNo
Rated voltage690V
Power loss6W
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864002R0081 | S804S-D8-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC

Number of poles (total)

4

Release characteristic

D

Over voltage category

3

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Rated current

8A

Concurrently switching neutral conductor

Number of protected poles

4

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Width in number of modular spacings

4

Pollution degree

3

Explosion-proof

Rated voltage

690V

Power loss

6W

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.