Technical specifications

Voltage typeAC/DC
Frequency50 - 60Hz
Rated current10A
Built-in depth82.5mm
Rated voltage400V
Rated insulation voltage Ui690V
Width in number of modular spacings4
Over voltage category4
Explosion-proofNo
Pollution degree3
Degree of protection (IP)IP20
Power loss6W
Current limiting class3
Release characteristicC
Connectable conductor cross section solid-core0 - 50mm²
Connectable conductor cross section multi-wired0 - 70mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Additional equipment possibleNo
Rated impulse withstand voltage Uimp8kV
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of protected poles4
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864002R0104 | S804S-C10-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated current

10A

Built-in depth

82.5mm

Rated voltage

400V

Rated insulation voltage Ui

690V

Width in number of modular spacings

4

Over voltage category

4

Explosion-proof

Pollution degree

3

Degree of protection (IP)

IP20

Power loss

6W

Current limiting class

3

Release characteristic

C

Connectable conductor cross section solid-core

0 .. 50mm²

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA