Aleta.hr
Main Product Image

2CCS864002R0105 | S804S-B10-R HIGH PERFORMANCE MCB

Code: 1858613

ManufacturerABB
Catalog number2CCS864002R0105
EAN code7612271209810

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installationNo
Built-in depth82.5mm
Frequency50 - 60Hz
Rated voltage400V
Pollution degree3
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Power loss6W
Number of protected poles4
Rated current10A
Current limiting class3
Over voltage category4
Rated insulation voltage Ui690V
Voltage typeAC/DC
Width in number of modular spacings4
Explosion-proofNo
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Additional equipment possibleNo
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired0 - 70mm²
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of poles (total)4
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864002R0105 | S804S-B10-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Rated voltage

400V

Pollution degree

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Power loss

6W

Number of protected poles

4

Rated current

10A

Current limiting class

3

Over voltage category

4

Rated insulation voltage Ui

690V

Voltage type

AC/DC

Width in number of modular spacings

4

Explosion-proof

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of poles (total)

4

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.