Aleta.hr
Main Product Image

2CCS864002R0134 | S804S-C13-R HIGH PERFORMANCE MCB

Code: 1858615

ManufacturerABB
Catalog number2CCS864002R0134
EAN code7612271210069

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Built-in depth82.5mm
Voltage typeAC/DC
Frequency50 - 60Hz
Rated voltage400V
Rated insulation voltage Ui690V
Rated current13A
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Number of protected poles4
Power loss8W
Width in number of modular spacings4
Concurrently switching neutral conductorNo
Current limiting class3
Explosion-proofNo
Suitable for flush-mounted installationNo
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Over voltage category4
Connectable conductor cross section solid-core0 - 50mm²
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Pollution degree3
Rated impulse withstand voltage Uimp8kV
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864002R0134 | S804S-C13-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Built-in depth

82.5mm

Voltage type

AC/DC

Frequency

50 .. 60Hz

Rated voltage

400V

Rated insulation voltage Ui

690V

Rated current

13A

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of protected poles

4

Power loss

8W

Width in number of modular spacings

4

Concurrently switching neutral conductor

Current limiting class

3

Explosion-proof

Suitable for flush-mounted installation

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Over voltage category

4

Connectable conductor cross section solid-core

0 .. 50mm²

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Pollution degree

3

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA