Aleta.hr
Main Product Image

2CCS864002R0205 | S804S-B20-R HIGH PERFORMANCE MCB

Code: 1858622

ManufacturerABB
Catalog number2CCS864002R0205
EAN code7612271209841

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Release characteristicB
Rated voltage400V
Frequency50 - 60Hz
Rated current20A
Voltage typeAC/DC
Suitable for flush-mounted installationNo
Pollution degree3
Number of protected poles4
Ambient temperature during operating-25 - 60°C
Current limiting class3
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Width in number of modular spacings4
Additional equipment possibleNo
Connectable conductor cross section multi-wired0 - 70mm²
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Concurrently switching neutral conductorNo
Explosion-proofNo
Number of poles (total)4
Degree of protection (IP)IP20
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section solid-core0 - 50mm²
Over voltage category4
Power loss14W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864002R0205 | S804S-B20-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Release characteristic

B

Rated voltage

400V

Frequency

50 .. 60Hz

Rated current

20A

Voltage type

AC/DC

Suitable for flush-mounted installation

Pollution degree

3

Number of protected poles

4

Ambient temperature during operating

-25 .. 60°C

Current limiting class

3

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Width in number of modular spacings

4

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

Explosion-proof

Number of poles (total)

4

Degree of protection (IP)

IP20

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section solid-core

0 .. 50mm²

Over voltage category

4

Power loss

14W

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.