Aleta.hr
Main Product Image

2CCS864002R0844 | S804S-C125-R HIGH PERFORMANCE

Code: 1858658

ManufacturerABB
Catalog number2CCS864002R0844
EAN code7612271207298

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationNo
Rated current125A
Rated voltage690V
Width in number of modular spacings4
Built-in depth82.5mm
Release characteristicC
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Number of protected poles4
Number of poles (total)4
Rated impulse withstand voltage Uimp8kV
Rated insulation voltage Ui690V
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Frequency50 - 60Hz
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Power loss37.6W
Flush-mounted installationNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864002R0844 | S804S-C125-R HIGH PERFORMANCE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated current

125A

Rated voltage

690V

Width in number of modular spacings

4

Built-in depth

82.5mm

Release characteristic

C

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Number of protected poles

4

Number of poles (total)

4

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Frequency

50 .. 60Hz

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Power loss

37.6W

Flush-mounted installation

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.