Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC
Rated voltage400V
Release characteristicB
Rated insulation voltage Ui500V
Rated current6A
Over voltage category3
Leakage current typeAC
Surge current capacity0.25kA
Pollution degree2
Current limiting class3
Rated fault current0.03A
Frequency50/60 Hz
Width in number of modular spacings4
Number of protected poles3
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Concurrently switching neutral conductorYes
Degree of protection (IP)IP2X
Number of poles (total)4
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core25 - 25mm²
With interlocking deviceYes
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R1065 | DS203NC B6 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC

Rated voltage

400V

Release characteristic

B

Rated insulation voltage Ui

500V

Rated current

6A

Over voltage category

3

Leakage current type

AC

Surge current capacity

0.25kA

Pollution degree

2

Current limiting class

3

Rated fault current

0.03A

Frequency

50/60 Hz

Width in number of modular spacings

4

Number of protected poles

3

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Concurrently switching neutral conductor

Degree of protection (IP)

IP2X

Number of poles (total)

4

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

25 .. 25mm²

With interlocking device

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.