Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated current10A
Rated voltage400V
Built-in depth69mm
Rated fault current0.03A
Release characteristicB
Rated insulation voltage Ui500V
Frequency50/60 Hz
Surge current capacity0.25kA
Current limiting class3
Over voltage category3
Width in number of modular spacings4
Leakage current typeAC
Pollution degree2
Degree of protection (IP)IP2X
Number of protected poles3
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of poles (total)4
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core25 - 25mm²
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
With interlocking deviceYes
Anti-nuisance tripping versionNo
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R1105 | DS203NC B10 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated current

10A

Rated voltage

400V

Built-in depth

69mm

Rated fault current

0.03A

Release characteristic

B

Rated insulation voltage Ui

500V

Frequency

50/60 Hz

Surge current capacity

0.25kA

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

4

Leakage current type

AC

Pollution degree

2

Degree of protection (IP)

IP2X

Number of protected poles

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of poles (total)

4

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

25 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

With interlocking device

Anti-nuisance tripping version

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.