Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Frequency50/60 Hz
Rated voltage400V
Number of protected poles3
Pollution degree2
Width in number of modular spacings4
Rated fault current0.03A
Voltage typeAC
Current limiting class3
Over voltage category3
Degree of protection (IP)IP2X
Surge current capacity0.25kA
Release characteristicC
Built-in depth69mm
Rated current13A
Leakage current typeAC
Rated insulation voltage Ui500V
With interlocking deviceYes
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core25 - 25mm²
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R1134 | DS203NC C13 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Frequency

50/60 Hz

Rated voltage

400V

Number of protected poles

3

Pollution degree

2

Width in number of modular spacings

4

Rated fault current

0.03A

Voltage type

AC

Current limiting class

3

Over voltage category

3

Degree of protection (IP)

IP2X

Surge current capacity

0.25kA

Release characteristic

C

Built-in depth

69mm

Rated current

13A

Leakage current type

AC

Rated insulation voltage Ui

500V

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

25 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.