Technical specifications

Voltage typeAC
Rated current13A
Built-in depth69mm
Current limiting class3
Rated fault current0.03A
Leakage current typeAC
Release characteristicB
Rated voltage400V
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Over voltage category3
Pollution degree2
Frequency50/60 Hz
Concurrently switching neutral conductorYes
Anti-nuisance tripping versionNo
Degree of protection (IP)IP2X
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Connectable conductor cross section solid-core25 - 25mm²
With interlocking deviceYes
Number of protected poles3
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Width in number of modular spacings4
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R1135 | DS203NC B13 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated current

13A

Built-in depth

69mm

Current limiting class

3

Rated fault current

0.03A

Leakage current type

AC

Release characteristic

B

Rated voltage

400V

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Over voltage category

3

Pollution degree

2

Frequency

50/60 Hz

Concurrently switching neutral conductor

Anti-nuisance tripping version

Degree of protection (IP)

IP2X

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Connectable conductor cross section solid-core

25 .. 25mm²

With interlocking device

Number of protected poles

3

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Width in number of modular spacings

4

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA