Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current0.03A
Built-in depth69mm
Rated voltage400V
Voltage typeAC
Rated insulation voltage Ui500V
Rated current20A
Release characteristicC
Pollution degree2
Surge current capacity0.25kA
Over voltage category3
Leakage current typeAC
Width in number of modular spacings4
Current limiting class3
Frequency50/60 Hz
Anti-nuisance tripping versionNo
Concurrently switching neutral conductorYes
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C
Number of poles (total)4
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of protected poles3
With interlocking deviceYes
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Suitable for flush-mounted installationNo
Degree of protection (IP)IP2X
Connectable conductor cross section solid-core25 - 25mm²
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R1204 | DS203NC C20 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current

0.03A

Built-in depth

69mm

Rated voltage

400V

Voltage type

AC

Rated insulation voltage Ui

500V

Rated current

20A

Release characteristic

C

Pollution degree

2

Surge current capacity

0.25kA

Over voltage category

3

Leakage current type

AC

Width in number of modular spacings

4

Current limiting class

3

Frequency

50/60 Hz

Anti-nuisance tripping version

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

4

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of protected poles

3

With interlocking device

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Suitable for flush-mounted installation

Degree of protection (IP)

IP2X

Connectable conductor cross section solid-core

25 .. 25mm²

Disconnection characteristic

Undelayed