Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current0.1A
Rated current8A
Current limiting class3
Release characteristicB
Leakage current typeAC
Rated insulation voltage Ui500V
Power loss4.2W
Surge current capacity0.25kA
Over voltage category3
Pollution degree2
Rated voltage400V
Built-in depth69mm
Voltage typeAC
Degree of protection (IP)IP2X
Width in number of modular spacings4
Frequency50/60 Hz
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section multi-wired1 - 25mm²
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 55°C
Number of protected poles3
Concurrently switching neutral conductorYes
Number of poles (total)4
Connectable conductor cross section solid-core25 - 25mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
With interlocking deviceYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R2085 | DS203NC B8 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated fault current

0.1A

Rated current

8A

Current limiting class

3

Release characteristic

B

Leakage current type

AC

Rated insulation voltage Ui

500V

Power loss

4.2W

Surge current capacity

0.25kA

Over voltage category

3

Pollution degree

2

Rated voltage

400V

Built-in depth

69mm

Voltage type

AC

Degree of protection (IP)

IP2X

Width in number of modular spacings

4

Frequency

50/60 Hz

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 55°C

Number of protected poles

3

Concurrently switching neutral conductor

Number of poles (total)

4

Connectable conductor cross section solid-core

25 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

With interlocking device