Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Surge current capacity0.25kA
Release characteristicB
Rated current10A
Rated insulation voltage Ui500V
Rated voltage400V
Leakage current typeAC
Rated fault current0.1A
Built-in depth69mm
Width in number of modular spacings4
Frequency50/60 Hz
Number of protected poles3
Degree of protection (IP)IP2X
Rated short-circuit breaking capacity according to IEC 60947-210kA
Pollution degree2
Number of poles (total)4
Connectable conductor cross section solid-core25 - 25mm²
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired1 - 25mm²
Suitable for flush-mounted installationNo
Over voltage category3
Flush-mounted installationNo
With interlocking deviceYes
Current limiting class3
Power loss5.6W
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity according to EN 610096kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R2105 | DS203NC B10 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Surge current capacity

0.25kA

Release characteristic

B

Rated current

10A

Rated insulation voltage Ui

500V

Rated voltage

400V

Leakage current type

AC

Rated fault current

0.1A

Built-in depth

69mm

Width in number of modular spacings

4

Frequency

50/60 Hz

Number of protected poles

3

Degree of protection (IP)

IP2X

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Pollution degree

2

Number of poles (total)

4

Connectable conductor cross section solid-core

25 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Suitable for flush-mounted installation

Over voltage category

3

Flush-mounted installation

With interlocking device

Current limiting class

3

Power loss

5.6W

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.