Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Leakage current typeAC
Release characteristicC
Built-in depth69mm
Rated fault current0.1A
Rated voltage400V
Rated current16A
Current limiting class3
Voltage typeAC
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Degree of protection (IP)IP2X
Ambient temperature during operating-25 - 55°C
Pollution degree2
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Width in number of modular spacings4
Number of protected poles3
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Connectable conductor cross section solid-core25 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-210kA
With interlocking deviceYes
Frequency50/60 Hz
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Power loss10W
Suitable for flush-mounted installationNo
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R2164 | DS203NC C16 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Leakage current type

AC

Release characteristic

C

Built-in depth

69mm

Rated fault current

0.1A

Rated voltage

400V

Rated current

16A

Current limiting class

3

Voltage type

AC

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP2X

Ambient temperature during operating

-25 .. 55°C

Pollution degree

2

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Width in number of modular spacings

4

Number of protected poles

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section solid-core

25 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

With interlocking device

Frequency

50/60 Hz

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Power loss

10W

Suitable for flush-mounted installation

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.