Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Built-in depth69mm
Voltage typeAC
Rated current20A
Rated insulation voltage Ui500V
Rated fault current0.1A
Release characteristicB
Surge current capacity0.25kA
Width in number of modular spacings4
Current limiting class3
Number of protected poles3
Frequency50/60 Hz
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core25 - 25mm²
Concurrently switching neutral conductorYes
Number of poles (total)4
Flush-mounted installationNo
Power loss11.8W
With interlocking deviceYes
Leakage current typeAC
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired1 - 25mm²
Suitable for flush-mounted installationNo
Degree of protection (IP)IP2X
Over voltage category3
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R2205 | DS203NC B20 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Built-in depth

69mm

Voltage type

AC

Rated current

20A

Rated insulation voltage Ui

500V

Rated fault current

0.1A

Release characteristic

B

Surge current capacity

0.25kA

Width in number of modular spacings

4

Current limiting class

3

Number of protected poles

3

Frequency

50/60 Hz

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

25 .. 25mm²

Concurrently switching neutral conductor

Number of poles (total)

4

Flush-mounted installation

Power loss

11.8W

With interlocking device

Leakage current type

AC

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Suitable for flush-mounted installation

Degree of protection (IP)

IP2X

Over voltage category

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version