Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Release characteristicB
Rated insulation voltage Ui500V
Rated voltage400V
Rated current25A
Leakage current typeAC
Pollution degree2
Rated fault current0.1A
Over voltage category3
Current limiting class3
Surge current capacity0.25kA
Built-in depth69mm
Degree of protection (IP)IP2X
Power loss10.3W
Frequency50/60 Hz
Width in number of modular spacings4
Anti-nuisance tripping versionNo
Concurrently switching neutral conductorYes
Number of protected poles3
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceYes
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Suitable for flush-mounted installationNo
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core25 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R2255 | DS203NC B25 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Release characteristic

B

Rated insulation voltage Ui

500V

Rated voltage

400V

Rated current

25A

Leakage current type

AC

Pollution degree

2

Rated fault current

0.1A

Over voltage category

3

Current limiting class

3

Surge current capacity

0.25kA

Built-in depth

69mm

Degree of protection (IP)

IP2X

Power loss

10.3W

Frequency

50/60 Hz

Width in number of modular spacings

4

Anti-nuisance tripping version

Concurrently switching neutral conductor

Number of protected poles

3

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Suitable for flush-mounted installation

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

25 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA