Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Release characteristicB
Rated insulation voltage Ui500V
Rated voltage400V
Pollution degree2
Over voltage category3
Current limiting class3
Surge current capacity0.25kA
Built-in depth69mm
Degree of protection (IP)IP2X
Power loss10.3W
Frequency50/60 Hz
Width in number of modular spacings4
Anti-nuisance tripping versionNo
Concurrently switching neutral conductorYes
Number of protected poles3
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceYes
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core25 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity according to EN 610096kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated current25A
Rated fault current0.1A
Leakage current typeAC
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R2255 | DS203NC B25 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Release characteristic

B

Rated insulation voltage Ui

500V

Rated voltage

400V

Pollution degree

2

Over voltage category

3

Current limiting class

3

Surge current capacity

0.25kA

Built-in depth

69mm

Degree of protection (IP)

IP2X

Power loss

10.3W

Frequency

50/60 Hz

Width in number of modular spacings

4

Anti-nuisance tripping version

Concurrently switching neutral conductor

Number of protected poles

3

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

25 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated current

25A

Rated fault current

0.1A

Leakage current type

AC

Number of poles (total)

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.