  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Voltage typeAC
Current limiting class3
Pollution degree2
Width in number of modular spacings4
Number of protected poles3
Surge current capacity0.25kA
Built-in depth69mm
Degree of protection (IP)IP2X
Rated insulation voltage Ui500V
Release characteristicC
Frequency50/60 Hz
Over voltage category3
Rated current16A
Leakage current typeAC
Rated fault current0.3A
Rated short-circuit breaking capacity according to IEC 60947-210kA
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core25 - 25mm²
Number of poles (total)4
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 55°C
Anti-nuisance tripping versionNo
With interlocking deviceYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256040R3164 | DS203NC C16 AC300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Voltage type

AC

Current limiting class

3

Pollution degree

2

Width in number of modular spacings

4

Number of protected poles

3

Surge current capacity

0.25kA

Built-in depth

69mm

Degree of protection (IP)

IP2X

Rated insulation voltage Ui

500V

Release characteristic

C

Frequency

50/60 Hz

Over voltage category

3

Rated current

16A

Leakage current type

AC

Rated fault current

0.3A

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

25 .. 25mm²

Number of poles (total)

4

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Anti-nuisance tripping version

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.