Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Rated current20A
Voltage typeAC
Built-in depth69mm
Current limiting class3
Connectable conductor cross section multi-wired1 - 25mm²
Rated insulation voltage Ui500V
Suitable for flush-mounted installationNo
Release characteristicB
Leakage current typeA
Number of protected poles3
Surge current capacity0.25kA
Rated fault current0.03A
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-210kA
Degree of protection (IP)IP2X
Pollution degree2
Width in number of modular spacings4
Over voltage category3
Number of poles (total)4
With interlocking deviceYes
Ambient temperature during operating-25 - 55°C
Frequency50/60 Hz
Connectable conductor cross section solid-core25 - 25mm²
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256140R1205 | DS203NC B20 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Rated current

20A

Voltage type

AC

Built-in depth

69mm

Current limiting class

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated insulation voltage Ui

500V

Suitable for flush-mounted installation

Release characteristic

B

Leakage current type

A

Number of protected poles

3

Surge current capacity

0.25kA

Rated fault current

0.03A

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Degree of protection (IP)

IP2X

Pollution degree

2

Width in number of modular spacings

4

Over voltage category

3

Number of poles (total)

4

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Frequency

50/60 Hz

Connectable conductor cross section solid-core

25 .. 25mm²

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.