Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage400V
Voltage typeAC
Release characteristicC
Current limiting class3
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Over voltage category3
Built-in depth69mm
Pollution degree2
Width in number of modular spacings4
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP2X
With interlocking deviceYes
Suitable for flush-mounted installationNo
Flush-mounted installationNo
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Power loss11.8W
Connectable conductor cross section solid-core25 - 25mm²
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorYes
Number of protected poles3
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Rated current20A
Rated fault current0.1A
Leakage current typeA
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256140R2204 | DS203NC C20 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Voltage type

AC

Release characteristic

C

Current limiting class

3

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Over voltage category

3

Built-in depth

69mm

Pollution degree

2

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP2X

With interlocking device

Suitable for flush-mounted installation

Flush-mounted installation

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Power loss

11.8W

Connectable conductor cross section solid-core

25 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Number of protected poles

3

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated current

20A

Rated fault current

0.1A

Leakage current type

A

Number of poles (total)

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.