Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC
Rated voltage400V
Release characteristicC
Rated insulation voltage Ui500V
Surge current capacity0.25kA
Current limiting class3
Over voltage category3
Frequency50/60 Hz
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to IEC 60947-210kA
Degree of protection (IP)IP2X
Width in number of modular spacings4
Pollution degree2
Concurrently switching neutral conductorYes
Power loss10.3W
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceYes
Ambient temperature during operating-25 - 55°C
Number of protected poles3
Connectable conductor cross section solid-core25 - 25mm²
Flush-mounted installationNo
Suitable for flush-mounted installationNo
Rated current25A
Rated fault current0.1A
Leakage current typeA
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256140R2254 | DS203NC C25 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC

Rated voltage

400V

Release characteristic

C

Rated insulation voltage Ui

500V

Surge current capacity

0.25kA

Current limiting class

3

Over voltage category

3

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Degree of protection (IP)

IP2X

Width in number of modular spacings

4

Pollution degree

2

Concurrently switching neutral conductor

Power loss

10.3W

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Number of protected poles

3

Connectable conductor cross section solid-core

25 .. 25mm²

Flush-mounted installation

Suitable for flush-mounted installation

Rated current

25A

Rated fault current

0.1A

Leakage current type

A

Number of poles (total)

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.