Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity according to IEC 60947-210kA
Built-in depth69mm
Pollution degree2
Number of protected poles3
Release characteristicC
Voltage typeAC
Rated fault current0.1A
Degree of protection (IP)IP2X
Frequency50/60 Hz
Over voltage category3
Leakage current typeA
Current limiting class3
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Rated voltage400V
Width in number of modular spacings4
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorYes
Power loss15.1W
Rated current32A
Ambient temperature during operating-25 - 55°C
Disconnection characteristicUndelayed
Number of poles (total)4
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Connectable conductor cross section solid-core25 - 25mm²
With interlocking deviceYes
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256140R2324 | DS203NC C32 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Built-in depth

69mm

Pollution degree

2

Number of protected poles

3

Release characteristic

C

Voltage type

AC

Rated fault current

0.1A

Degree of protection (IP)

IP2X

Frequency

50/60 Hz

Over voltage category

3

Leakage current type

A

Current limiting class

3

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Rated voltage

400V

Width in number of modular spacings

4

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Power loss

15.1W

Rated current

32A

Ambient temperature during operating

-25 .. 55°C

Disconnection characteristic

Undelayed

Number of poles (total)

4

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Connectable conductor cross section solid-core

25 .. 25mm²

With interlocking device

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.