Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth68.9mm
Voltage typeAC
Release characteristicC
Rated current16A
Rated insulation voltage Ui500V
Current limiting class3
Surge current capacity0.25kA
Leakage current typeAC
Rated fault current0.01A
Rated voltage230V
Pollution degree2
Suitable for flush-mounted installationNo
Width in number of modular spacings1
Number of protected poles1
Degree of protection (IP)IP2X
Concurrently switching neutral conductorNo
Power loss2.4W
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Over voltage category3
Connectable conductor cross section multi-wired1 - 35mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core35 - 35mm²
Rated short-circuit breaking capacity according to EN 6100910kA
Number of poles (total)2
With interlocking deviceYes
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275051R0164 | DSE201 M C16 AC10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

68.9mm

Voltage type

AC

Release characteristic

C

Rated current

16A

Rated insulation voltage Ui

500V

Current limiting class

3

Surge current capacity

0.25kA

Leakage current type

AC

Rated fault current

0.01A

Rated voltage

230V

Pollution degree

2

Suitable for flush-mounted installation

Width in number of modular spacings

1

Number of protected poles

1

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Power loss

2.4W

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

35 .. 35mm²

Rated short-circuit breaking capacity according to EN 61009

10kA

Number of poles (total)

2

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.