Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage230V
Voltage typeAC
Width in number of modular spacings1
Over voltage category3
Connectable conductor cross section multi-wired1 - 35mm²
Built-in depth68.9mm
Surge current capacity0.25kA
Rated current6A
Rated fault current0.03A
Concurrently switching neutral conductorNo
Leakage current typeAC
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core35 - 35mm²
Suitable for flush-mounted installationNo
Rated insulation voltage Ui500V
Current limiting class3
Frequency50/60 Hz
Power loss1.8W
Degree of protection (IP)IP2X
Release characteristicC
Number of protected poles1
With interlocking deviceYes
Rated short-circuit breaking capacity according to EN 6100910kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275051R1064 | DSE201 M C6 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Voltage type

AC

Width in number of modular spacings

1

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 35mm²

Built-in depth

68.9mm

Surge current capacity

0.25kA

Rated current

6A

Rated fault current

0.03A

Concurrently switching neutral conductor

Leakage current type

AC

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

35 .. 35mm²

Suitable for flush-mounted installation

Rated insulation voltage Ui

500V

Current limiting class

3

Frequency

50/60 Hz

Power loss

1.8W

Degree of protection (IP)

IP2X

Release characteristic

C

Number of protected poles

1

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation