Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui500V
Rated fault current0.03A
Surge current capacity0.25kA
Power loss3.0W
Frequency50/60 Hz
Voltage typeAC
Leakage current typeAC
Width in number of modular spacings1
Over voltage category3
Number of protected poles1
Rated short-circuit breaking capacity according to IEC 60947-210kA
Degree of protection (IP)IP2X
Suitable for flush-mounted installationNo
Release characteristicC
Pollution degree2
Current limiting class3
Rated current20A
Concurrently switching neutral conductorNo
Built-in depth68.9mm
Rated voltage230V
Disconnection characteristicUndelayed
Connectable conductor cross section solid-core35 - 35mm²
With interlocking deviceYes
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired1 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275051R1204 | DSE201 M C20 AC30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Surge current capacity

0.25kA

Power loss

3.0W

Frequency

50/60 Hz

Voltage type

AC

Leakage current type

AC

Width in number of modular spacings

1

Over voltage category

3

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Degree of protection (IP)

IP2X

Suitable for flush-mounted installation

Release characteristic

C

Pollution degree

2

Current limiting class

3

Rated current

20A

Concurrently switching neutral conductor

Built-in depth

68.9mm

Rated voltage

230V

Disconnection characteristic

Undelayed

Connectable conductor cross section solid-core

35 .. 35mm²

With interlocking device

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

1 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.