Technical specifications

Voltage typeAC
Release characteristicC
Current limiting class3
Over voltage category3
Suitable for flush-mounted installationNo
Frequency50/60 Hz
Power loss1.8W
Connectable conductor cross section solid-core35 - 35mm²
Concurrently switching neutral conductorNo
Degree of protection (IP)IP2X
Connectable conductor cross section multi-wired1 - 35mm²
Surge current capacity0.25kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated insulation voltage Ui500V
Rated current6A
Pollution degree2
Number of poles (total)2
With interlocking deviceYes
Leakage current typeAC
Ambient temperature during operating-25 - 55°C
Width in number of modular spacings1
Rated fault current0.1A
Rated voltage230V
Flush-mounted installationNo
Number of protected poles1
Built-in depth68.9mm
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275051R2064 | DSE201 M C6 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Release characteristic

C

Current limiting class

3

Over voltage category

3

Suitable for flush-mounted installation

Frequency

50/60 Hz

Power loss

1.8W

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Degree of protection (IP)

IP2X

Connectable conductor cross section multi-wired

1 .. 35mm²

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated insulation voltage Ui

500V

Rated current

6A

Pollution degree

2

Number of poles (total)

2

With interlocking device

Leakage current type

AC

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

1

Rated fault current

0.1A

Rated voltage

230V

Flush-mounted installation

Number of protected poles

1

Built-in depth

68.9mm

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed