Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth68.9mm
Over voltage category3
Rated current25A
Rated voltage230V
Current limiting class3
Voltage typeAC
Leakage current typeAC
Release characteristicC
Surge current capacity0.25kA
Rated insulation voltage Ui500V
Rated fault current0.3A
Frequency50/60 Hz
Anti-nuisance tripping versionNo
Power loss3.3W
Width in number of modular spacings1
Connectable conductor cross section multi-wired1 - 35mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity according to EN 6100910kA
Connectable conductor cross section solid-core35 - 35mm²
Flush-mounted installationNo
With interlocking deviceYes
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Disconnection characteristicUndelayed
Number of poles (total)2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Suitable for flush-mounted installationNo
Pollution degree2
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP2X
Number of protected poles1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275051R3254 | DSE201 M C25 AC300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

68.9mm

Over voltage category

3

Rated current

25A

Rated voltage

230V

Current limiting class

3

Voltage type

AC

Leakage current type

AC

Release characteristic

C

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Frequency

50/60 Hz

Anti-nuisance tripping version

Power loss

3.3W

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

1 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity according to EN 61009

10kA

Connectable conductor cross section solid-core

35 .. 35mm²

Flush-mounted installation

With interlocking device

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Number of poles (total)

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Suitable for flush-mounted installation

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP2X

Number of protected poles

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.