Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP30
Number of poles4
Type of control elementToggle
Number of auxiliary contacts as normally open contact-
Rated permanent current Iu20A
Number of auxiliary contacts as normally closed contact1
Motor drive optionalNo
Motor drive integratedNo
Overload release current setting20 - 20A
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Rated voltage110 - 550V
Number of auxiliary contacts as change-over contact1
Adjustment range undelayed short-circuit release400 - 400A
Suitable for DIN rail (top hat rail) mountingYes
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release400 - 400A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseYes
Complete device with protection unitYes
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

027011 | DRX100 STRUJNI PR. 4P 20A 10KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP30

Number of poles

4

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

-

Rated permanent current Iu

20A

Number of auxiliary contacts as normally closed contact

1

Motor drive optional

Motor drive integrated

Overload release current setting

20 .. 20A

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Rated voltage

110 .. 550V

Number of auxiliary contacts as change-over contact

1

Adjustment range undelayed short-circuit release

400 .. 400A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Adjustment range short-term delayed short-circuit release

400 .. 400A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

With under voltage release

Complete device with protection unit

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

10kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.