Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Built-in depth44mm
Frequency50 - 60Hz
Rated current0.5A
Voltage typeAC
Rated voltage400V
Release characteristicD
Rated insulation voltage Ui500V
Current limiting class-
Over voltage category-
Pollution degree2
Width in number of modular spacings2
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired- - -mm²
Number of protected poles2
Concurrently switching neutral conductorNo
Number of poles (total)2
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating- - -°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Suitable for flush-mounted installationYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403729 | TX3 MCB 2P D0,5 6000A BIC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Built-in depth

44mm

Frequency

50 .. 60Hz

Rated current

0.5A

Voltage type

AC

Rated voltage

400V

Release characteristic

D

Rated insulation voltage Ui

500V

Current limiting class

-

Over voltage category

-

Pollution degree

2

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

- .. -mm²

Number of protected poles

2

Concurrently switching neutral conductor

Number of poles (total)

2

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

- .. -°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Suitable for flush-mounted installation