Technical specifications

Number of protected poles2
Release characteristicD
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationYes
Rated voltage400V
Rated current0.5A
Over voltage category-
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class-
Additional equipment possibleYes
Built-in depth44mm
Connectable conductor cross section multi-wired- - -mm²
Connectable conductor cross section solid-core- - -mm²
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating- - -°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

403729 | TX3 MCB 2P D0,5 6000A BIC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Number of protected poles

2

Release characteristic

D

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Rated voltage

400V

Rated current

0.5A

Over voltage category

-

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

-

Additional equipment possible

Built-in depth

44mm

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

- .. -°C