Aleta.hr
Main Product Image

407783 | DX3 2P C13 6000A/10KA

Code: 1860258

ManufacturerLegrand
Catalog number407783
EAN code3245064077835

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC
Suitable for flush-mounted installationYes
Rated voltage400V
Rated current13A
Width in number of modular spacings2
Built-in depth44mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Release characteristicC
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section multi-wired1.5 - 25mm²
Connectable conductor cross section solid-core1.5 - 35mm²
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui500V
Number of poles (total)2
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Additional equipment possibleYes
Frequency50 - 60Hz
Pollution degree2
Concurrently switching neutral conductorNo
Over voltage category-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407783 | DX3 2P C13 6000A/10KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated voltage

400V

Rated current

13A

Width in number of modular spacings

2

Built-in depth

44mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Release characteristic

C

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Connectable conductor cross section solid-core

1.5 .. 35mm²

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of poles (total)

2

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Additional equipment possible

Frequency

50 .. 60Hz

Pollution degree

2

Concurrently switching neutral conductor

Over voltage category

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.