Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Rated voltage400V
Pollution degree3
Over voltage category-
Frequency50 - 60Hz
Release characteristicB
Current limiting class-
Width in number of modular spacings4.5
Degree of protection (IP)IP20
Rated insulation voltage Ui500V
Number of protected poles3
Rated current40A
Built-in depth47mm
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Ambient temperature during operating-25 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Suitable for flush-mounted installationYes
Additional equipment possibleYes
Connectable conductor cross section multi-wired1.5 - 35mm²
Connectable conductor cross section solid-core1.5 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Number of poles (total)3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409733 | DX3 3P B40 25KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Rated voltage

400V

Pollution degree

3

Over voltage category

-

Frequency

50 .. 60Hz

Release characteristic

B

Current limiting class

-

Width in number of modular spacings

4.5

Degree of protection (IP)

IP20

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated current

40A

Built-in depth

47mm

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Ambient temperature during operating

-25 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Suitable for flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Connectable conductor cross section solid-core

1.5 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Number of poles (total)

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.