Technical specifications

Release characteristicB
Voltage typeAC
Pollution degree3
Over voltage category-
Suitable for flush-mounted installationYes
Current limiting class-
Frequency50 - 60Hz
Built-in depth47mm
Rated current63A
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Width in number of modular spacings4.5
Number of protected poles3
Rated insulation voltage Ui500V
Rated voltage400V
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section solid-core1.5 - 50mm²
Connectable conductor cross section multi-wired1.5 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp6kV
Ambient temperature during operating-25 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

409735 | DX3 3P B63 25KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Release characteristic

B

Voltage type

AC

Pollution degree

3

Over voltage category

-

Suitable for flush-mounted installation

Current limiting class

-

Frequency

50 .. 60Hz

Built-in depth

47mm

Rated current

63A

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Width in number of modular spacings

4.5

Number of protected poles

3

Rated insulation voltage Ui

500V

Rated voltage

400V

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section solid-core

1.5 .. 50mm²

Connectable conductor cross section multi-wired

1.5 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

6kV

Ambient temperature during operating

-25 .. 70°C