Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)IP30
Type of control elementToggle
Number of poles3
Rated permanent current Iu160A
Number of auxiliary contacts as normally closed contact1
Number of auxiliary contacts as normally open contact-
Motor drive optionalNo
Overload release current setting160 - 160A
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Rated voltage110 - 550V
Number of auxiliary contacts as change-over contact1
Adjustment range undelayed short-circuit release1600 - 1600A
With under voltage releaseYes
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release1600 - 1600A
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingYes
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

427232 | DRX250 MT 160A 3P 36KA

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP30

Type of control element

Toggle

Number of poles

3

Rated permanent current Iu

160A

Number of auxiliary contacts as normally closed contact

1

Number of auxiliary contacts as normally open contact

-

Motor drive optional

Overload release current setting

160 .. 160A

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Rated voltage

110 .. 550V

Number of auxiliary contacts as change-over contact

1

Adjustment range undelayed short-circuit release

1600 .. 1600A

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

1600 .. 1600A

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.