Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth60mm
Rated current63A
Release characteristicB
Rated insulation voltage Ui440V
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Rated voltage240V
Number of poles (total)1
Voltage typeAC
Power loss5.5W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Frequency50 - 50Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Over voltage category3
Flush-mounted installationYes
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 75°C
Width in number of modular spacings1
Degree of protection (IP)IP20
Pollution degree2
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Additional equipment possibleYes
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B63/1-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

60mm

Rated current

63A

Release characteristic

B

Rated insulation voltage Ui

440V

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated voltage

240V

Number of poles (total)

1

Voltage type

AC

Power loss

5.5W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Frequency

50 .. 50Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Over voltage category

3

Flush-mounted installation

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 75°C

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Additional equipment possible

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.