Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Frequency50 - 50Hz
Release characteristicB
Rated current1.5A
Explosion-proofNo
Built-in depth60mm
Rated insulation voltage Ui440V
Over voltage category3
Power loss8.8W
Current limiting class3
Width in number of modular spacings4
Rated voltage240V
Pollution degree2
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Number of protected poles4
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section multi-wired1 - 25mm²
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Number of poles (total)4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B1,5/4-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Frequency

50 .. 50Hz

Release characteristic

B

Rated current

1.5A

Explosion-proof

Built-in depth

60mm

Rated insulation voltage Ui

440V

Over voltage category

3

Power loss

8.8W

Current limiting class

3

Width in number of modular spacings

4

Rated voltage

240V

Pollution degree

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Number of protected poles

4

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Number of poles (total)

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.