Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicB
Voltage typeAC
Built-in depth60mm
Rated current2A
Frequency50 - 50Hz
Rated insulation voltage Ui440V
Over voltage category3
Degree of protection (IP)IP20
Power loss5.6W
Explosion-proofNo
Width in number of modular spacings4
Pollution degree2
Rated voltage240V
Current limiting class3
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Connectable conductor cross section solid-core1 - 25mm²
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Flush-mounted installationYes
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Ambient temperature during operating-25 - 75°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B2/4-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Voltage type

AC

Built-in depth

60mm

Rated current

2A

Frequency

50 .. 50Hz

Rated insulation voltage Ui

440V

Over voltage category

3

Degree of protection (IP)

IP20

Power loss

5.6W

Explosion-proof

Width in number of modular spacings

4

Pollution degree

2

Rated voltage

240V

Current limiting class

3

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Connectable conductor cross section solid-core

1 .. 25mm²

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Concurrently switching neutral conductor

Additional equipment possible

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Ambient temperature during operating

-25 .. 75°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.