  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated current35A
Number of protected poles4
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated voltage240V
Frequency50 - 50Hz
Built-in depth60mm
Power loss7.6W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Additional equipment possibleYes
Over voltage category3
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Concurrently switching neutral conductorNo
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Pollution degree2
Release characteristicB
Width in number of modular spacings4
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B35/4-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated current

35A

Number of protected poles

4

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated voltage

240V

Frequency

50 .. 50Hz

Built-in depth

60mm

Power loss

7.6W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Additional equipment possible

Over voltage category

3

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Concurrently switching neutral conductor

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Pollution degree

2

Release characteristic

B

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20