Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage240V
Frequency50 - 50Hz
Rated current40A
Built-in depth60mm
Release characteristicB
Voltage typeAC
Current limiting class3
Over voltage category3
Rated insulation voltage Ui440V
Pollution degree2
Width in number of modular spacings4
Power loss13.6W
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Explosion-proofNo
Rated impulse withstand voltage Uimp4kV
Number of protected poles4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Number of poles (total)4
Flush-mounted installationYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B40/4-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

240V

Frequency

50 .. 50Hz

Rated current

40A

Built-in depth

60mm

Release characteristic

B

Voltage type

AC

Current limiting class

3

Over voltage category

3

Rated insulation voltage Ui

440V

Pollution degree

2

Width in number of modular spacings

4

Power loss

13.6W

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Explosion-proof

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

4

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Number of poles (total)

4

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.