Technical specifications

Built-in depth60mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of poles (total)4
Rated current50A
Release characteristicB
Current limiting class3
Concurrently switching neutral conductorNo
Rated voltage240V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Frequency50 - 50Hz
Flush-mounted installationYes
Rated insulation voltage Ui440V
Power loss17.6W
Connectable conductor cross section solid-core1 - 25mm²
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Width in number of modular spacings4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Over voltage category3
Voltage typeAC
Degree of protection (IP)IP20
Additional equipment possibleYes
Number of protected poles4
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B50/4-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

60mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of poles (total)

4

Rated current

50A

Release characteristic

B

Current limiting class

3

Concurrently switching neutral conductor

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 50Hz

Flush-mounted installation

Rated insulation voltage Ui

440V

Power loss

17.6W

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Over voltage category

3

Voltage type

AC

Degree of protection (IP)

IP20

Additional equipment possible

Number of protected poles

4

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C