Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles3
Release characteristicC
Built-in depth60mm
Number of poles (total)3
Rated current63A
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated voltage240V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Frequency50 - 50Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Pollution degree2
Current limiting class3
Over voltage category3
Additional equipment possibleYes
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 75°C
Width in number of modular spacings3
Flush-mounted installationYes
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Rated insulation voltage Ui440V
Connectable conductor cross section multi-wired1 - 25mm²
Power loss16.5W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C63/3-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles

3

Release characteristic

C

Built-in depth

60mm

Number of poles (total)

3

Rated current

63A

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Frequency

50 .. 50Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Pollution degree

2

Current limiting class

3

Over voltage category

3

Additional equipment possible

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 75°C

Width in number of modular spacings

3

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Rated insulation voltage Ui

440V

Connectable conductor cross section multi-wired

1 .. 25mm²

Power loss

16.5W

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.