Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Pollution degree2
Connectable conductor cross section solid-core1 - 25mm²
Current limiting class3
Rated current30A
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
Width in number of modular spacings4
Frequency50 - 50Hz
Voltage typeAC
Rated voltage240V
Release characteristicC
Built-in depth60mm
Additional equipment possibleYes
Over voltage category3
Power loss12W
Degree of protection (IP)IP20
Number of protected poles4
Flush-mounted installationYes
Ambient temperature during operating-25 - 75°C
Number of poles (total)4
Concurrently switching neutral conductorNo
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C30/4-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 25mm²

Current limiting class

3

Rated current

30A

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Width in number of modular spacings

4

Frequency

50 .. 50Hz

Voltage type

AC

Rated voltage

240V

Release characteristic

C

Built-in depth

60mm

Additional equipment possible

Over voltage category

3

Power loss

12W

Degree of protection (IP)

IP20

Number of protected poles

4

Flush-mounted installation

Ambient temperature during operating

-25 .. 75°C

Number of poles (total)

4

Concurrently switching neutral conductor

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.