Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth60mm
Release characteristicC
Width in number of modular spacings4
Explosion-proofNo
Frequency50 - 50Hz
Rated voltage240V
Over voltage category3
Pollution degree2
Current limiting class3
Voltage typeAC
Rated current40A
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Number of protected poles4
Degree of protection (IP)IP20
Power loss13.6W
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C40/4-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

60mm

Release characteristic

C

Width in number of modular spacings

4

Explosion-proof

Frequency

50 .. 50Hz

Rated voltage

240V

Over voltage category

3

Pollution degree

2

Current limiting class

3

Voltage type

AC

Rated current

40A

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Number of protected poles

4

Degree of protection (IP)

IP20

Power loss

13.6W

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.