Rated voltage240V
Built-in depth60mm
Rated current6A
Voltage typeAC
Flush-mounted installationYes
Release characteristicC
Frequency50 - 50Hz
Current limiting class3
Power loss4.8W
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Number of protected poles4
Additional equipment possibleYes
Width in number of modular spacings4
Rated insulation voltage Ui440V
Ambient temperature during operating-25 - 75°C
Explosion-proofNo
Pollution degree2
Concurrently switching neutral conductorNo
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C6/4-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

240V

Built-in depth

60mm

Rated current

6A

Voltage type

AC

Flush-mounted installation

Release characteristic

C

Frequency

50 .. 50Hz

Current limiting class

3

Power loss

4.8W

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of protected poles

4

Additional equipment possible

Width in number of modular spacings

4

Rated insulation voltage Ui

440V

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Pollution degree

2

Concurrently switching neutral conductor

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA