Technical specifications

Rated insulation voltage Ui440V
Release characteristicD
Built-in depth60mm
Rated current0.5A
Frequency50 - 50Hz
Voltage typeAC
Rated voltage240V
Pollution degree2
Over voltage category3
Current limiting class3
Width in number of modular spacings70.8
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Suitable for flush-mounted installationYes
Degree of protection (IP)IP20
Number of poles (total)4
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-D0,5/4-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui

440V

Release characteristic

D

Built-in depth

60mm

Rated current

0.5A

Frequency

50 .. 50Hz

Voltage type

AC

Rated voltage

240V

Pollution degree

2

Over voltage category

3

Current limiting class

3

Width in number of modular spacings

70.8

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Suitable for flush-mounted installation

Degree of protection (IP)

IP20

Number of poles (total)

4

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4