Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles4
Built-in depth60mm
Rated voltage240V
Number of poles (total)4
Frequency50 - 50Hz
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Power loss7.6W
Degree of protection (IP)IP20
Release characteristicB
Pollution degree2
Voltage typeAC
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating-25 - 75°C
Width in number of modular spacings4
Connectable conductor cross section solid-core1 - 25mm²
Rated current35A
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationYes
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Current limiting class3
Explosion-proofNo
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B35/4-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles

4

Built-in depth

60mm

Rated voltage

240V

Number of poles (total)

4

Frequency

50 .. 50Hz

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Power loss

7.6W

Degree of protection (IP)

IP20

Release characteristic

B

Pollution degree

2

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

-25 .. 75°C

Width in number of modular spacings

4

Connectable conductor cross section solid-core

1 .. 25mm²

Rated current

35A

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Current limiting class

3

Explosion-proof

Additional equipment possible

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.