Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Number of poles (total)4
Rated current25A
Number of protected poles4
Built-in depth60mm
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated voltage240V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Power loss11.2W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Flush-mounted installationYes
Over voltage category3
Pollution degree2
Width in number of modular spacings4
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Frequency50 - 50Hz
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C25/4-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Number of poles (total)

4

Rated current

25A

Number of protected poles

4

Built-in depth

60mm

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

11.2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Over voltage category

3

Pollution degree

2

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Frequency

50 .. 50Hz

Concurrently switching neutral conductor

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.