Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Number of poles (total)4
Voltage typeAC
Built-in depth60mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V14kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated voltage240V
Power loss13.6W
Concurrently switching neutral conductorNo
Flush-mounted installationYes
Frequency50 - 50Hz
Over voltage category3
Pollution degree2
Rated current40A
Current limiting class3
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Number of protected poles4
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Width in number of modular spacings4
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Degree of protection (IP)IP20
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C40/4-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Number of poles (total)

4

Voltage type

AC

Built-in depth

60mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated voltage

240V

Power loss

13.6W

Concurrently switching neutral conductor

Flush-mounted installation

Frequency

50 .. 50Hz

Over voltage category

3

Pollution degree

2

Rated current

40A

Current limiting class

3

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Number of protected poles

4

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.